OUR LOCATION
 
(561)624-9609 (800) 624-0114
Serving Palm Beach, Martin, and St. Lucie Counties
407 Commerce Way 4A
Jupiter, Fl 33458
 
 
  Home
  About us
  Products
   
Vacuflo
Nutone
Accessories page
InterVac
  Our services
  Contact Us
     
 

Quiet, clean and easy to use.
That's the built-in advantage from NuTone!

With a NuTone built-in Central Vacuum System, there's no cumbersome vacuum cleaner to lug from room to room or up and down stairs.

A NuTone Central Vacuum System is one of America’s “most wanted” built-in appliances. Quiet, powerful and versatile, they offer convenience and value because they make cleaning every corner of your house unbelievably easy.
Simply insert the lightweight hose into a wall inlet. Powerful cleaning suction begins immediately. Remove the hose and the system shuts off. Best of all, there’s no cumbersome vacuum cleaner to lug from room to room or up and down stairs.
And unlike conventional vacuum cleaners, a NuTone central vacuum system is a long-lasting built-in convenience that actually adds value to your home.

Performance Series Power
Unit - Fan-Cooled
2-Stage Universal Bypass Motor
Model CV350

Additional Models Available

Performance Series Power
Unit - 2-Stage Thru-Flow Motor
Model CV352

Performance Series Power
Unit - Fan-Cooled 3-Stage
Universal Bypass Motor
Model CV353

Performance Series Power
Unit - Two Fan-Cooled 2-Stage
Universal Bypass Motors
Model CV450

'Cyclonic' Action Bagless Filtration
Model CV554

'Cyclonic' Action Bagless Filtration
Model CV556

'Cyclonic' Two Fan-Cooled 2-Stage
Universal Bypass Motors
Model CV570

Advantage Series Power Unit
Model CV653

Advantage Series Power Unit
Model CV750

Advantage Series Power Unit
Model CV850


Performance Series Power
Unit - Fan-Cooled
2-Stage Universal Bypass Motor
Model CV350

  • Inlet on Power Unit. Makes it easy to clean the area where the Power Unit is located.
  • Convenient switch. Located on Power Unit, turns system on and off.
  • No special wiring needed. Power Units (except CV850, CV750 and CV450) operate on dedicated 15 amp circuit. 120V AC, 50-60Hz circuit 20 amp dedicated circuit recommended for CV750 and CV450 units. CV850 requires 15A 240V inlet. All feature overload protection and built-in low voltage switch controls.
  • Rugged steel housings. Handsome, durable designer white polyester appliance finish.
  • Mounting bracket. Provides fast, easy, secure wall-mounting.
  • 6-ft. cord. 3-pronged, grounded plug for convenience outlet.
  • Large 6-gallon capacity. Needs emptying only about twice a year.
  • UL Listed

to top

Additional Models Available

  • CV350 - Performance Series Power Unit - Fan-Cooled 2-Stage Universal Bypass Motor
  • CV352 - Performance Series Power Unit - 2-Stage Thru-Flow Motor
  • CV353 - Performance Series Power Unit - Fan-Cooled 3-Stage Universal Bypass Motor
  • CV450 - Performance Series Power Unit - Two Fan-Cooled 2-Stage Universal Bypass Motors
  • CV554 - 'Cyclonic' Action Bagless Filtration
  • CV556 - 'Cyclonic' Action Bagless Filtration
  • CV570 - 'Cyclonic' Two Fan-Cooled 2-Stage Universal Bypass Motors
  • CV653 - Advantage Series Power Unit
  • CV750 - Advantage Series Power Unit
  • CV850 - Advantage Series Power Unit

to top

 

Performance Series Power
Unit - 2-Stage Thru-Flow Motor
Model CV352

  • Inlet on Power Unit. Makes it easy to clean the area where the Power Unit is located.
  • Convenient switch. Located on Power Unit, turns system on and off.
  • No special wiring needed. Power Units (except CV850, CV750 and CV450) operate on dedicated 15 amp circuit. 120V AC, 50-60Hz circuit 20 amp dedicated circuit recommended for CV750 and CV450 units. CV850 requires 15A 240V inlet. All feature overload protection and built-in low voltage switch controls.
  • Rugged steel housings. Handsome, durable designer white polyester appliance finish.
  • Mounting bracket. Provides fast, easy, secure wall-mounting.
  • 6-ft. cord. 3-pronged, grounded plug for convenience outlet.
  • Large 6-gallon capacity. Needs emptying only about twice a year.
  • UL Listed
  • The CV352 provides economical operation for smaller homes, apartments and condos, with 7.5 amps for economical operation. Its smaller size also makes it ideal for modular homes. Recommended for homes up to 2000 sq. ft.

to top

 

Performance Series Power
Unit - Fan-Cooled 3-Stage
Universal Bypass Motor
Model CV353

  • Inlet on Power Unit. Makes it easy to clean the area where the Power Unit is located.
  • Convenient switch. Located on Power Unit, turns system on and off.
  • No special wiring needed. Power Units (except CV850, CV750 and CV450) operate on dedicated 15 amp circuit. 120V AC, 50-60Hz circuit 20 amp dedicated circuit recommended for CV750 and CV450 units. CV850 requires 15A 240V inlet. All feature overload protection and built-in low voltage switch controls.
  • Rugged steel housings. Handsome, durable designer white polyester appliance finish.
  • Mounting bracket. Provides fast, easy, secure wall-mounting.
  • 6-ft. cord. 3-pronged, grounded plug for convenience outlet.
  • Large 6-gallon capacity. Needs emptying only about twice a year. Large 6-gallon capacity. Needs emptying only about twice a year.
  • UL Listed
  • The CV353 delivers efficient cleaning from a single 3-stage motor. Ideal for homes up to 3,500 sq. feet. 6-gallon capacity.

to top

 

Performance Series Power
Unit - Two Fan-Cooled 2-Stage
Universal Bypass Motors

Model CV450

  • Inlet on Power Unit. Makes it easy to clean the area where the Power Unit is located.
  • Convenient switch. Located on Power Unit, turns system on and off.
  • No special wiring needed. Power Units (except CV850, CV750 and CV450) operate on dedicated 15 amp circuit. 120V AC, 50-60Hz circuit 20 amp dedicated circuit recommended for CV750 and CV450 units. CV850 requires 15A 240V inlet. All feature overload protection and built-in low voltage switch controls.
  • Rugged steel housings. Handsome, durable designer white polyester appliance finish.
  • Mounting bracket. Provides fast, easy, secure wall-mounting.
  • 6-ft. cord. 3-pronged, grounded plug for convenience outlet.
  • Large 6-gallon capacity. Needs emptying only about twice a year. Large 6-gallon capacity. Needs emptying only about twice a year.
  • UL Listed
  • This popular power unit delivers excellent cleaning performance from dual motors and a combined 2 1/2 horsepower rating. Easily handles homes up to 5,000 sq. feet. 6-gallon capacity.

to top

 

'Cyclonic' Action Bagless Filtration
Model CV554

  • Inlet on Power Unit. Makes it easy to clean the area where the Power Unit is located.
  • Convenient switch. Located on Power Unit, turns system on and off.
  • No special wiring needed. Power Units (except CV850, CV750 and CV450) operate on dedicated 15 amp circuit. 120V AC, 50-60Hz circuit 20 amp dedicated circuit recommended for CV750 and CV450 units. CV850 requires 15A 240V inlet. All feature overload protection and built-in low voltage switch controls.
  • Rugged steel housings. Handsome, durable designer white polyester appliance finish.
  • Mounting bracket. Provides fast, easy, secure wall-mounting.
  • 6-ft. cord. 3-pronged, grounded plug for convenience outlet.
  • Large 6-gallon capacity. Needs emptying only about twice a year. Large 6-gallon capacity. Needs emptying only about twice a year.
  • UL Listed
  • Cyclonic Power Unit - Single Fan-Cooled 2-Stage Universal Bypass Motor. Enjoy dependable performance with this single two-stage motor unit. Ideal for small to mid-size homes up to 3,000 sq. feet. 6-gallon capacity.

to top

 

'Cyclonic' Action Bagless Filtration
Model CV556
  • Inlet on Power Unit. Makes it easy to clean the area where the Power Unit is located.
  • Convenient switch. Located on Power Unit, turns system on and off.
  • No special wiring needed. Power Units (except CV850, CV750 and CV450) operate on dedicated 15 amp circuit. 120V AC, 50-60Hz circuit 20 amp dedicated circuit recommended for CV750 and CV450 units. CV850 requires 15A 240V inlet. All feature overload protection and built-in low voltage switch controls.
  • Rugged steel housings. Handsome, durable designer white polyester appliance finish.
  • Mounting bracket. Provides fast, easy, secure wall-mounting.
  • 6-ft. cord. 3-pronged, grounded plug for convenience outlet.
  • Large 6-gallon capacity. Needs emptying only about twice a year. Large 6-gallon capacity. Needs emptying only about twice a year.
  • UL Listed
  • Cyclonic Power Unit - Single Fan-Cooled 3-Stage Universal Bypass Motor. This unit delivers superior vacuuming suction with a dependable three-stage motor. Dirt is collected in bottom of 6-gallon canister through 'cyclonic' force. Recommended for homes up to 3,500 sq. ft.

to top

 

'Cyclonic' Two Fan-Cooled 2-Stage
Universal Bypass Motors
Model CV570
  • Inlet on Power Unit. Makes it easy to clean the area where the Power Unit is located.
  • Convenient switch. Located on Power Unit, turns system on and off.
  • No special wiring needed. Power Units (except CV850, CV750 and CV450) operate on dedicated 15 amp circuit. 120V AC, 50-60Hz circuit 20 amp dedicated circuit recommended for CV750 and CV450 units. CV850 requires 15A 240V inlet. All feature overload protection and built-in low voltage switch controls.
  • Rugged steel housings. Handsome, durable designer white polyester appliance finish.
  • Mounting bracket. Provides fast, easy, secure wall-mounting.
  • 6-ft. cord. 3-pronged, grounded plug for convenience outlet.
  • Large 6-gallon capacity. Needs emptying only about twice a year. Large 6-gallon capacity. Needs emptying only about twice a year.
  • UL Listed
  • Cyclonic Power Unit - Two Fan-Cooled 2-Stage Universal Bypass Motors. Enjoy powerful cleaning performance, designed for larger homes or light commercial applications. Large, 7-gallon dirt canister is easily removed for emptying. Recommended for homes up to 5,000 sq. ft.

to top

 

Advantage Series Power Unit
Model CV653

  • Inlet on Power Unit. Makes it easy to clean the area where the Power Unit is located.
  • Convenient switch. Located on Power Unit, turns system on and off.
  • No special wiring needed. Power Units (except CV850, CV750 and CV450) operate on dedicated 15 amp circuit. 120V AC, 50-60Hz circuit 20 amp dedicated circuit recommended for CV750 and CV450 units. CV850 requires 15A 240V inlet. All feature overload protection and built-in low voltage switch controls.
  • Rugged steel housings. Handsome, durable designer white polyester appliance finish.
  • Mounting bracket. Provides fast, easy, secure wall-mounting.
  • 6-ft. cord. 3-pronged, grounded plug for convenience outlet.
  • Large 6-gallon capacity. Needs emptying only about twice a year. Large 6-gallon capacity. Needs emptying only about twice a year.
  • UL Listed
  • Efficient quiet performance from a single motor for up to 3,500 sq. ft. homes. Sound insulation lowers sound levels of power unit. Unit features system indicator light. Muffler included. 6-gallon capacity.

to top

 

Advantage Series Power Unit
Model CV750
  • Inlet on Power Unit. Makes it easy to clean the area where the Power Unit is located.
  • Convenient switch. Located on Power Unit, turns system on and off.
  • No special wiring needed. Power Units (except CV850, CV750 and CV450) operate on dedicated 15 amp circuit. 120V AC, 50-60Hz circuit 20 amp dedicated circuit recommended for CV750 and CV450 units. CV850 requires 15A 240V inlet. All feature overload protection and built-in low voltage switch controls.
  • Rugged steel housings. Handsome, durable designer white polyester appliance finish.
  • Mounting bracket. Provides fast, easy, secure wall-mounting.
  • 6-ft. cord. 3-pronged, grounded plug for convenience outlet.
  • Large 6-gallon capacity. Needs emptying only about twice a year. Large 6-gallon capacity. Needs emptying only about twice a year.
  • UL Listed
  • Where powerful cleaning performance and reduced power unit sound levels are needed, the CV750 is your choice. Two-motor unit for homes up to 5,000 sq. ft. Includes sound insulation for reduced sound levels, system indicator light and muffler.

to top

 

Advantage Series Power Unit
Model CV850
  • Inlet on Power Unit. Makes it easy to clean the area where the Power Unit is located.
  • Convenient switch. Located on Power Unit, turns system on and off.
  • No special wiring needed. Power Units (except CV850, CV750 and CV450) operate on dedicated 15 amp circuit. 120V AC, 50-60Hz circuit 20 amp dedicated circuit recommended for CV750 and CV450 units. CV850 requires 15A 240V inlet. All feature overload protection and built-in low voltage switch controls.
  • Rugged steel housings. Handsome, durable designer white polyester appliance finish.
  • Mounting bracket. Provides fast, easy, secure wall-mounting.
  • 6-ft. cord. 3-pronged, grounded plug for convenience outlet.
  • Needs emptying only about twice a year. CV850 unit has 8-gallon capacity.
  • UL Listed
  • For maximum cleaning performance in larger homes or light commercial applications, choose NuTone's 240V model CV850. Recommended for up to 12,000 sq. ft. With two 3-stage motors, the CV850 packs more power in a compact package. Large 8-gallon capacity dirt receptacle bag. Includes sound insulation, two mufflers, and system status indicator light.

to top

 

*Free Estimates
Call for appointment
(800) 976-8323

 

 
 
 
Home | About us | Products | Our services | Contact Us
 
 
Ezdoit web design, marketing (c) 2004, Central Vacuum Connection